MRI Scans Could Leave Toxic Traces in Your Body, Scientists Warn!

MRI Scans Could Leave Toxic Traces in Your Body, Scientists Warn!

A contrast MRI is a type of magnetic resonance imaging (MRI) scan that uses a special dye to improve the visibility of tissues, organs, and blood vessels. This contrast agent —often containing gadolinium—is injected into the bloodstream, making certain areas stand out more clearly in the images.

Scientists have discovered a potential link between MRI contrast dye and toxic material buildup in the body. Researchers at the University of New Mexico (UNM) found that oxalic acid, a molecule present in foods like spinach, chocolate, and almonds, may interact with gadolinium, the heavy metal used in MRI contrast agents. This interaction could lead to the formation of harmful nanoparticles that infiltrate organs.

In a new paper published in the journal Magnetic Resonance Imaging, a team led by Brent Wagner, MD, professor in the Department of Internal Medicine in the UNM School of Medicine, sought to explain the formation of the nanoparticles, which have been associated with serious health problems in the kidneys and other organs.

While most patients experience no adverse effects, some have reported reactions ranging from mild swelling and headaches to more severe conditions like nephrogenic systemic fibrosis, which can cause skin thickening and organ damage. The findings suggest that individuals undergoing MRI scans with contrast might want to avoid Vitamin C supplements, as they can increase oxalic acid levels.

This discovery could lead to new safety recommendations for MRI procedures.

How Gadolinium is used in MRI scans?

Gadolinium-based contrast agents (GBCAs) are used in MRI scans to enhance the visibility of soft tissues. Gadolinium is a heavy metal with unique magnetic properties, making it ideal for MRI imaging. However, because raw gadolinium is toxic, it’s chemically bonded to molecules (called chelators) to make it safe for medical use.

How it Works:
  1. Injection – The contrast agent is injected into the bloodstream, usually through an IV.
  2. Magnetic Interaction – Gadolinium influences the magnetic fields used in MRI, causing tissues with high blood flow (like tumors or inflamed areas) to appear brighter.
  3. Better Imaging – This enhancement helps doctors differentiate between normal and abnormal tissues, making it easier to detect brain disorders, cancer, and vascular diseases.
Despite its benefits, there has been concern over gadolinium retention in the body, especially in patients with kidney issues. Research continues into safer alternatives and better ways to remove any lingering traces.

“The worst disease caused by MRI contrast agents is nephrogenic systemic fibrosis,” said Professor Brent Wagner. “People have succumbed after just a single dose.” The condition can cause a thickening and hardening of the skin, heart and lungs and cause painful contracture of the joints."

The medical community has mixed reactions to MRI contrast agents, particularly those containing gadolinium. While they are widely used to enhance imaging, concerns have grown over potential side effects and long-term retention in the body.

Scientists are exploring safer alternatives and ways to minimize gadolinium retention in the body.

German MedTech Firm Invented Smaller and Lighter MRI Scanner Helps in Saving Lives of Sick Babie

Shrunken MRI scanner helps in saving lives of sick babies

Spectrum Instrumentation PC-cards play a key role in brand-new MRI for babies

Bangalore – 17 May 2021. MRI scanners are a key diagnostic tool but they are big, very heavy and need liquid helium to cool them. Neoscan Solutions invented an MRI scanner much smaller and lighter which could be placed directly in the children's ward of the hospital, to keep journeys short and to scan sick babies in their sleep. Key to the much smaller design is the use of digitizers and AWGs by Spectrum Instrumentation that offer sub-nano second, coherence precision to generate the scanner-signals and capture the results.

Current MRI scanners weigh around eight tons and therefore need to be located on floors that can take this weight, which means either specially reinforced floors or locating them in a basement. They also require ca. 40 square metres for the scanner and all the support equipment. Lastly, they need to be supercooled with liquid helium, which needs special handling.

"Having worked with MRI scanners for many years, I recognised the problem," explained Stefan Roell, Founder of Neoscan Solutions in Germany. "Scanning a sick child usually means a long journey out of the ward to the scanner and babies may need support equipment that is not easily transportable. Because of this, sometimes an MRI-scan is not even done. We have designed an MRI scanner specifically for new-borns and infants which means that the hole in the middle is only 30cm in diameter, not 60cm. As a result, the scanner is much smaller (170cm x 150cm x 110cm) and can go through standard doorways. With a weight of only 2000 kg, it can be located on standard floors and, needing only ten square metres, it can be installed in a spare room directly on the children's ward. Carrying a sleeping baby only a few meters to the MRI is a big advantage, saving a long journey through the building and the need for sedatives to keep the baby motionless for the scan."

Innovations needed


The technology and field strength of the Neoscan machine is identical to current scanners so that no new clinical studies are required to validate it. Achieving this needed several innovations by the company. Firstly, to shrink the size, the team had to develop a dry magnet that would create the standard 1.5 Tesla field inside the hole, but without requiring liquid helium. This is done by an inner, cylindrical magnet generating 2.5T and then an outer cylindrical magnet that counteracts the inner field to provide strong, active magnet shielding so that there are no stray magnetic field left beyond about 1m from the device's cover.

The second innovation was in the control electronics. Current MRI scanners typically require three big racks of specially developed electronics, that have been custom designed and built by the MRI manufacturer. Neoscan Solutions chose a different approach. The team uses a PC which runs the software that Neoscan has created plus high-end measurement PC-cards from Spectrum Instrumentation. The signals for the MRI are generated by the M4i.6620-x8 and M2p.6546-x4 AWGs (Arbitrary Waveform Generators) and then analysed using an M2p.5968-x4 digitizer. The system uses Spectrum's SCAPP software drivers that enable a Graphics Processor with 5000 cores to perform the parallel processing, instead of using only 8 or 16 cores of a normal CPU.

Sub nano-second precision of Spectrum cards


"As a start-up, we could not afford to create specialized hardware and so we used this route of high quality, standard cards providing a platform to run our software on," added Dr Roell. "This meant that we could focus our skills on the software development with very fast development cycles in the knowledge that the hardware was already tried and tested. This was only possible because of the design quality of the Spectrum cards. For MRI, it is vital that there is phase coherence in the 64MHz signals, otherwise there will be cancellation effects. In practice, that means that the AWG and matching digitizer have to have sub-nanosecond coherence precision, which the Spectrum cards achieve. During the research phase, it was hard to determine this from the specifications of the cards provided by the various suppliers that we contacted, as it is a rather unusual level of detail. However, Spectrum was outstanding in helping us with technical support both in the specification of the best cards to use and then again during the implementation. A rival proposal took weeks longer to arrive and was grossly over-specified and over-priced as they had not made the effort to understand the detail of our project."

Neoscan will be shortly installing its first devices in German hospitals where it can be seen in operation by prospective customers as it takes images of babies. The certification process with a CE mark is expected to be completed before the end of 2021. Neoscan's website offers more information under: www.neoscan-solutions.com


Dr Roell concluded by saying: "This approach of a readily available hardware platform running specially designed software worked very well for us as it has enabled us to create a product much faster. I think it is a very elegant solution that could be used for many other complex machines such as CT scanners and Ultrasound machines, especially as it enables innovative new approaches to be easily tried and evaluated just through software changes."


About Spectrum Instrumentation

Spectrum Instrumentation, founded in 1989, uses a versatile modular design to create a wide range of digitizer and generator products as PC-cards (PCIe and PXIe) and stand-alone Ethernet units (LXI) with an industry-leading, five-year warranty. In 30 years, it has gained customers all around the world, including many A-brand industry-leaders and practically all prestigious universities. The company is headquartered near Hamburg, Germany, and known for its outstanding support that comes directly from the design engineers. More information about Spectrum can be found at www.spectrum-instrumentation.com

Globally unique MRI Guarantee: The Highest MRI Sfety with hearing implants from MED-EL

Worry-free, safe magnetic resonance imaging (MRI) with MED-EL cochlear, middle ear or bone conduction implants – now with lifetime guarantee. For immediate access to an MRI examination without surgery, discomfort or hearing downtime.



INNSBRUCK, Austria, Feb. 2, 2021 /PRNewswire/ -- The innovative design of the implant magnets from MED-EL is completely safe during an MRI examination. As of now, the global innovation leader in hearing solutions is emphasising this safety with an MRI guarantee that is as yet unmatched. With this, MED-EL is the only manufacturer to accept liability for damage to all cochlear implants that have been produced since 1994, all bone conduction implants and the current generation of middle ear implants during an MRI examination. Users of these MED-EL implants can therefore not only undergo an MRI examination at any time without the need for surgical removal of the magnets* and without pain – they can also do so safely and with no worries.

Three in four people will require an MRI scan in the next ten years**. Whether routine or in an emergency: patients with severe hearing loss may face a challenge if the magnets in their hearing implants are not safe inside the MRI machine. This requires the prior surgical removal of the magnets. Hearing ability is temporarily lost and long-term damage to the implant may occur. If the patient declines surgery, they may suffer from severe pain during the examination coupled with the possible dislocation of the magnet.

The highest MRI safety with MED-EL


Not all implants carry this risk. As a leading manufacturer of implantable hearing solutions, MED-EL has for more than twenty years made a point of only producing implants that offer outstanding MRI safety. To emphasise this requirement, MED-EL offers the unique MRI Guarantee which means no damage to the device during an MRI examination. MED-EL is thereby the only manufacturer to issue its users with a comprehensive global lifetime MRI guarantee.

"The MRI Guarantee ensures more safety, comfort and peace of mind during MRI examinations," says Alexander Hofer, Corporate Director of Product Management at MED-EL. "We take care of our users for a lifetime and they should have the opportunity to make use of everything modern medicine has to offer. This is especially important when diagnosing serious illnesses such as cancer, tumours, multiple sclerosis or Parkinson's disease," stresses Alexander Hofer.

Being able to undergo magnetic resonance imaging immediately can also be crucial in emergencies such as an accident. A further benefit: people with severe hearing loss only have to go without their ability to hear during the MRI examination itself.

Innovative technology excludes complications


The safe and reliable technology from MED-EL ensures that the magnets in place during the magnetic resonance imaging are neither damaged, nor dislocate causing pain. Only the external components, such as the audio processor, must be removed prior to the MRI examination.

"MED-EL has developed its own highly innovative, patented cochlear implant system with state-of-the-art implant magnets and their fixation within the implant. This excludes, for example, a dislocation of the magnet during an MRI scan, which can be very painful for the patient," says Martin Zimmerling, Head of Implant Development at MED-EL. "With the SYNCHRONY cochlear implants, the magnet can freely rotate and align according to the magnetic field of the MRI scan. With the altered implant design, undesirable forces during the MRI scan and the associated pain for the patient are reliably prevented," explains Martin Zimmerling. "We are proud not only that the latest generation of our cochlear implants is compatible with MRI machines, but that all cochlear implants produced since 1994 are too, as well as all bone conduction implants and the latest middle ear implant from MED-EL."

The increasing significance of magnetic resonance imaging makes it clear how important it is to provide people with severe hearing loss access to this gentle and high-resolution imaging process. MED-EL rises to this responsibility and provides extra security and comfort for all users with the MRI Guarantee.

*So as to avoid imaging difficulties in the immediate vicinity of the implant, it may be advisable to remove the magnets.
**Source: OECD. Magnetic resonance imaging exams 2016–2019.

About MED-EL:

MED-EL Medical Electronics, a leader in implantable hearing solutions, is driven by a mission to overcome hearing loss as a barrier to communication. The Austrian-based, privately owned business was co-founded by industry pioneers Ingeborg and Erwin Hochmair, whose groundbreaking research led to the development of the world's first micro-electronic multi-channel cochlear implant (CI), which was successfully implanted in 1977 and was the basis for what is known as the modern CI today. This laid the foundation for the successful growth of the company in 1990, when they hired their first employees. To date, MED-EL has grown to more than 2,200 employees from around 75 nations and has 30 locations worldwide. The company offers the widest range of implantable and non-implantable solutions to treat all types of hearing loss, enabling people in 124 countries to enjoy the gift of hearing with the help of a MED-EL device. MED-EL's hearing solutions include cochlear and middle ear implant systems, a combined Electric Acoustic Stimulation hearing implant system, auditory brainstem implants as well as surgical and non-surgical bone conduction devices.

Market Reports

Market Report & Surveys
IndianWeb2.com © all rights reserved